IEC 62776 PDF

Buy IEC Ed. Double-capped LED lamps designed to retrofit linear fluorescent lamps – Safety specifications from SAI Global. IEC DOUBLE-CAPPED LED LAMPS DESIGNED TO RETROFIT LINEAR FLUORESCENT LAMPS – SAFETY SPECIFICATIONS. SS IEC Title, Double-capped LED lamps designed to retrofit linear fluorescent lamps – Safety specifications. Edition, No. of Pages,

Author: Doutaur Temi
Country: Madagascar
Language: English (Spanish)
Genre: Finance
Published (Last): 4 April 2016
Pages: 239
PDF File Size: 18.7 Mb
ePub File Size: 19.48 Mb
ISBN: 618-6-27174-467-4
Downloads: 9339
Price: Free* [*Free Regsitration Required]
Uploader: Voodookus

Opened lamps or inspection of internal component parts of the lamp may be required to verify conformity with Clauses 11, 12 and 14 of this standard. Ice assessment project in view of the above principles, the standard mainly focuses on the evaluation of: No flashover or breakdown shall occur during the test.

Publication of IEC/EN – Safety for Double-capped LED Lamps

The LED replacement starter shall be marked as in Figure 4. NOTE 2 This standard includes photobiological safety.

This site uses Akismet to reduce spam. NOTE 1 The rated voltage or voltage range of the lamp can 26776 from the open circuit voltage.

IEC 62776 Approved T8 Light LED CE and Rohs certificates Retrofit T8 Direct Replacement

The standard is only applicable to LED lamp to meet the following conditions: Recommendations for whole product testing or batch testing are given in Annex A. In Maygeneral safety requirements IEC If lamps are marked with a voltage range, rated voltage is taken as the maximum of the voltage range marked unless the manufacturer declares another voltage as the most critical one.

TOP Related Posts  I821D FORM PDF

Figure 8 — Test configuration for touch current measurement. C exemption working voltage not exceeding 25Vr. Such LED lamps are designed for replacement without requiring any internal modification of the luminaire. The symbol is under development as IEC Pr Figure 4 — LED replacement starter h Provide information on the ingress of dust and water.

The length of the lamp 67276 not change significantly within the specified ambient temperature range of the lamp.

OVE webshop – IEC /COR

The specific update project 1 based on the above 3 aspects, according to the standard update are: It is then gradually raised to the full value. Dimension A is measured after the lamp is stabilised and 62776 as Aoperating. The publication of this standard gives a suitable safety guide for LED manufacturers exporting to EU market.

Size and gauge requirements: The main contents of update. In cases of doubt regarding the suitability 662776 the application the manufacturer of this lamp should be consulted. In the case of doubt based on the inspection of the lamp and the examination of the lamp circuit diagram, and in agreement with the manufacturer or responsible vendor, lamps shall be specially oec so that a fault condition can be simulated and shall be submitted for testing see Clause Following IECSection 8, basic insulation during lamp insertion is sufficient.

TOP Related Posts  IEC 61400-2 PDF

The content of the instructions shall include the following. Further requirements on failing safe are given in Clause Variation of dimension A due 6. Example for a retrofit ie. Figure 7 — Schematic steps of removing a fluorescent lamp and inserting a double-capped LED lamp designed to retrofit linear fluorescent lamp 5.

Labeling requirements are 26776 to power ballast lamps? Intertek is a leading Total Quality Assurance provider to industries worldwide. The marking shall be legible after the test. The lamp under test shall consist of a iecc unit, operated at its rated supply voltage. For the replacement of the tube, the LED lamp tube of the interior light of the lamp needs to be changed, which is not within the scope of this standard.

The requirements in this standard are given for general lighting service excluding for example explosive atmospheres.